| Symptom / Error | FRU / Action in Sequence |
|---|---|
| 10X 101 Interrupt failure 102 Timer failure 103 Timer interrupt failure 104 Protected mode failure 105 Last 8042 command not accepted 107 NMI test failure 108 Timer bus test failure 109 Low meg-chip select test | 1. System board |
| 110 (Planar parity) | 1. Go to "Memory Checkout" on page 12 of the HMM 2. DIMM card 3. Detach the expansion unit if it is attached to the computer 4. System board |
| 111 (I/O parity) | 1. Go to "Memory Checkout" on page 12 of the HMM 2. Port replicator 3. System board |
| 127 (Cache error) | 1. CPU mini-cartridge 2. System board |
| 158 (Hard disk password was not set even though the supervisor password is set) | 1. Set the password for hard disk drive |
| 159 (Hard disk password is not set the same as the supervisor password) | 1. Set the correct password for hard disk drive |
| 161 (Dead battery) | 1. Go to "Checking the Backup Battery" on page 16 of the HMM 2. Backup battery 3. System board |
| 163 (Time and date were not set) | 1. Set time and date 2. System board |
| 173 (Configuration data was lost) | 1. Select OK in the error screen; then set the time and date 2. Backup battery 3. System board |
| 174 (Configuration error: Perform "Checking the Installed Devices List" on page 35 of the HMM before changing any FRUs) | 1. Check device configuration 2. Hard disk drive assembly 3. System board |
| 175, 177, 178 175 EEPROM CRC #1 error 177 Supervisor password check sum error 178 EEPROM is not functional | 1. System board |
| 183 (Incorrect password entered at the supervisor password prompt) | 1. Have the user examine the password |
| 184 (Power-on password check sum error) | 1. Reset the power-on password in Easy-Setup |
| 185 (The start-up sequence is not valid. Suspect that power was off when the startup sequence was being updated) | 1. Reset the startup sequence in Easy-Setup |
| 186 | 1. System Board. |
| 188 (EEPROM CRC #2 error) | 1. System board. |
| 190 (A depleted battery pack was installed when the power was on) | 1. Go to "Checking the Battery Pack" on page 16 of the HMM |
| 191XX (PM initialization error) | 1. System board |
| 192 (A fan error) | 1. Fan 2. System board |
| 195 (The configuration read from the hibernation area does not match the actual configuration) | 1. Check if the configuration was changed. For example, check if a DIMM card was added |
| 196 (A read error occurred in the hibernation area of the hard disk drive) | 1. Run the hard disk drive test 2. Reseat the HDD flat cable 3. Hard disk drive |
| 199XX (Resume error) | 1. System board |
| 1XX | 1. System board. |
| 225 (An unsupported memory module) | 1. Check if a supported DIMM card is installed 2. DIMM card 3. System board |
| 2XX 201 Memory data error 202 Memory line error 00-15 203 Memory line error 16-23 205 Memory test failure on on-board memory 221 ROM to RAM remap error | 1. Go to "Memory Checkout" on page 12 of the HMM 2. DIMM card 3. System board |
| 301, 303, 304, 305, 3XX 301 Keyboard error | 1. Go to "Keyboard or Auxiliary Input Device Checkout" on page 11 of the HMM 2. Keyboard 3. External numeric keypad 4. External keyboard 5. Keyboard/mouse cable 6. System board |
| 601, 6XX 601 Diskette drive or controller error | 1. Go to "Diskette Drive Checkout" on page 11 of the HMM 2. Diskette drive assembly 3. Diskette 4. System board |
| 602 (Diskette read error) | 1. Go to "Diskette Drive Checkout" on page 11 of the HMM 2. Diskette 3. Diskette drive assembly |
| 604 (Unacceptable ID was read from the diskette drive) | 1. Go to "Diskette Drive Checkout" on page 11 of the HMM 2. Diskette drive assembly 3. System board |
| 11XX 1101 Serial_A test failure | 1. Serial device 2. Communication cable 3. System board |
| 12XX 1201 Serial_B test failure | 1. System board (infrared) |
| 17XX 1701 Hard disk controller failure 1780, 1790 Hard disk 0 error 1781, 1791 Hard disk 1 error | 1. HDD flat cable 2. Hard disk drive 3. System board |
| 1801 (An unsupported port replicator) | 1. Make sure that the correct port replicator is connected. See page 79 of the HMM |
| 24XX 2401 System board video error | 1. System board. |
| 808X 8081 PCMCIA presence test failure. (PCMCIA revision number also checked) 8082 PCMCIA register test failure | 1. PC Card slot assembly 2. PCMCIA device 3. System board |
| 860X (Pointing device error when TrackPoint is disabled) 8601 System bus error - 8042 mouse interface 8602 External mouse error 8603 System bus error or mouse error | 1. External mouse 2. External keyboard 3. System board |
| 861X (Pointing device error when TrackPoint is enabled) 8611 System bus error - I/F between 8042 and IPDC 8612 TrackPoint error 8613 System board or TrackPoint error | 1. Reseat the keyboard cable on the system board 2. Keyboard 3. External mouse 4. System board |
| I9990301 I9990302 I9990305 I9990301 Hard disk error I9990302 Invalid hard disk boot record I9990305 No bootable device | 1. Check that the operating system is installed in the hard disk drive. If not, install the operating system 2. Reseat the boot device 3. Reseat the HDD flat cable 4. Check the startup sequence for the correct boot device 5. Check that the operating system has no failure and is installed correctly |
| I9990303 (Bank - 2 flash ROM check sum error) | 1. System board |
| Other codes not listed above | 1. Go to "Undetermined Problems" on page 31 of the HMM |
进入上海新宇笔记本维修主力站点 |
|
免费服务电话:800 820 9120 |
笔 |
| 我们的地址:上海市南丹东路228弄3号楼402室 | |
| 我们的电话:021-64283052 64283432 | |
| 我们的传真:021-54254762 | |
| E-mail:13918440336@sohu.com | |
| 24小时报修热线:13391203680 赵先生(维修工程师) | |
最拿手维修: 松下,NEC,TCL,宏基,三星,LG,清华紫光 笔记本液晶屏维修,笔记本主板维修,笔记本电池维修... |
|
>>与我们客户服务取得联系<<< |
|
2005-2006 上海新宇笔记本维修中心公司地址:上海市南丹东路228弄3号楼402室
我们的电话:021-64283052 64283432 ; 我们的传真:021-54254762 E-mail:13918440336@sohu.com