Symptom / Error FRU / Action in Sequence
0200

Failure Fixed Disk
1. Reseat hard disk drive.
2. Load Setup Defaults in BIOS Setup Utility.
3. Hard disk drive
4. System board
021x
Keyboard error
Go to "Keyboard and Auxiliary Input Device Checkout"
023x
Memory error
1. DIMM
2. BIOS ROM
3. System board
0250
System battery error
Replace backup battery (RTC) and run BIOS Setup Utility to reconfigure the system time, then reboot the system.
0251
System CMOS checksum bad
- Default configuration used
1. Backup battery (RTC)
2. Run BIOS Setup Utility to reconfigure the system, then reboot the system.
0260
System timer error
 
1. Back up battery (RTC)
2. Run BIOS Setup Utility to reconfigure the system, then reboot the system.
3. System board
0270
Real time clock error
 
1. Back up battery (RTC)
2. Run BIOS Setup Utility to reconfigure the system, then reboot the system.
3. System board
0271
Check date and time setting
 
1. Run BIOS Setup Utility and verify date and time.
2. Backup battery (RTC)
3. System board
0281
Memory size found by POST differed from CMOS
1. Load Setup Defaults in the BIOS Setup Utility.
2. DIMM
3. System board
02Bx
Diskette drive A error
 
1. Check that the drive is defined with the proper diskette type in BIOS Setup Utility.
2. Go to "Diskette Drive Checkout"
02D0
System cache error - Cache disabled
1. CPU card
2. System board

进入上海新宇笔记本维修主力站点

免费服务电话:800 820 9120
















我们的地址:上海市南丹东路228弄3号楼402室
我们的电话:021-64283052 64283432
我们的传真:021-54254762
E-mail:13918440336@sohu.com
24小时报修热线:13391203680 赵先生(维修工程师)

最拿手维修:

IBM,DELL,SONY,华硕,东芝,联想,惠普,富士,苹果

松下,NEC,TCL,宏基,三星,LG,清华紫光

笔记本液晶屏维修,笔记本主板维修,笔记本电池维修...

>>与我们客户服务取得联系<<<

 


返回首页 网站地图


2005-2006 上海新宇笔记本维修中心公司地址:上海市南丹东路228弄3号楼402室
我们的电话:021-64283052 64283432 ; 我们的传真:021-54254762 E-mail:13918440336@sohu.com