Error code
Symptom or error
FRU or action, in sequence
0175 Bad CRC1, stop POST task. The EEPROM checksum is not correct. System board
0187 EAIA data access error System board
0188 Invalid RFID serialization information area or bad CRC2.
 
System board
0189 Invalid RFID configuration information area.
 
System board
0190 Critical low battery error. 1. Charge the battery pack.
2. Battery pack.
0200 Fixed disk failure 1. Reseat the hard disk drive.
2. Load Setup Defaults in IBM BIOS Setup Utility.
3. Hard disk drive.
4. System board.
021x Stuck key.
Keyboard or auxiliary input device error
Run interactive tests of the keyboard and the auxiliary input device.
0220 Monitor type does not match CMOS
 
Load Setup Defaults in IBM BIOS Setup Utility.
0230 Shadow RAM failure at offset nnnn System board
0231 System RAM failure at offset nnnn 1. DIMM
2. System board.
0232 Extended RAM failure at offset nnnn 1. DIMM
2. System board.
0250 System battery is dead - replace and run setup Replace the backup battery and run IBM BIOS Setup Utility to reset the time and date.
0251 System CMOS checksum bad - Default configuration used Replace the backup battery and run IBM BIOS Setup Utility to reset the time and date.
0252 Password checksum bad. Reset the password by running IBM BIOS Setup Utility.
0260 System timer error 1. Replace the backup battery and run IBM BIOS Setup Utility to reset the time and date.
2. System board.
0270 Real time clock error 1. Replace the backup battery and run IBM BIOS Setup Utility to reset the time and date.
2. System board.
0271 Date and time error Run IBM BIOS Setup Utility to reset the time and date.
0280 Boot incomplete error - Default configuration used 1. Load Setup Defaults in IBM BIOS Setup Utility.
2. DIMM.
3. System board.
02B2 Incorrect drive A type. Diskette drive.
02D0 System cache error  
02F4 EISA CMOS not writable. 1. Load Setup Defaults in IBM BIOS Setup Utility.
2. Replace the backup battery.
3. System board.
02F5 DIMM test failure 1. DIMM.
2. System board.
02F6 Software NMI failure 1. DIMM.
2. System board.
02F7 Fail-safe timer NMI failure 1. DIMM.
2. System board.
1801 Attached docking station is not supported. Shut down the computer and remove it from the docking station.
 

进入上海新宇笔记本维修主力站点

免费服务电话:800 820 9120
















我们的地址:上海市南丹东路228弄3号楼402室
我们的电话:021-64283052 64283432
我们的传真:021-54254762
E-mail:13918440336@sohu.com
24小时报修热线:13391203680 赵先生(维修工程师)

最拿手维修:

IBM,DELL,SONY,华硕,东芝,联想,惠普,富士,苹果

松下,NEC,TCL,宏基,三星,LG,清华紫光

笔记本液晶屏维修,笔记本主板维修,笔记本电池维修...

>>与我们客户服务取得联系<<<

 


返回首页 网站地图


2005-2006 上海新宇笔记本维修中心公司地址:上海市南丹东路228弄3号楼402室
我们的电话:021-64283052 64283432 ; 我们的传真:021-54254762 E-mail:13918440336@sohu.com