| Error code | Symptom | FRU or action, in sequence | |
|---|---|---|---|
| 0175 | Bad CRC1, stop POST task, the EEPROM checksum is not correct. |
| |
| 0176 |
System Security, the system has been tampered with. |
| |
| 0177 | Bad SVP data, stop POST task. Checksum of the supervisor password in the EEPROM is not correct. |
| |
| 0182 | Bad CRC2. Enter BIOS Setup and load Setup defaults. Checksum of the CRS2 setting in the EEPROM is not correct. |
| |
| 0185 | Bad startup sequence settings. Enter BIOS Setup and load Setup defaults. |
| |
| 0187 |
EAIA data access error, the access to EEPROM is failed (read or write). |
| |
| 0188 |
Invalid RFID serialization information area or bad CRC2, the EEPROM checksum is not correct (block #0, 1). EEPROM CRC2 is not correct (block #6). |
| |
| 0189 |
Invalid RFID configuration information area, the EEPROM checksum is not correct (block #4, 5). |
| |
| 0190 |
Critical low-battery error |
| |
| 0191 |
System Security, Invalid Remote Change requested. |
| |
| 0192 |
System Security, Embedded Security hardware tamper detected. |
| |
| 0193 | RF antenna has been remove. RFID antenna has been r moved, which was once installed. |
| |
| 0194 | The computer has been carried through a security gate. The computer is carried through the security gate (portal gate). |
| |
| 0195 | Security hardware tamper detected |
| |
| 0196 | Security hardware removed |
| |
| 0197 |
Invalid remote change requested |
| |
| 0199 |
System Security, Security password retry count exceeded. |
| |
| 01C8 | More than one modem devices are found. Remove one of them. Press the Esc key to continue. |
| |
| 01C9 | More than one Ethernet devices are found. Remove one of them Press the Esc key to continue. |
| |
| 0200 |
Hard disk error, the Fixed disk is not working or not configured properly. |
| |
| 0210 | Stuck key |
| |
| 0211 | Keyboard error - keyboard not working |
| |
| 0212 | Keyboard Controller Failed - Keyboard controller failed test. |
| |
| 0213 | Keyboard locked - Unlock key switch |
| |
| 0220 |
Monitor type error, monitor type does not match the one specified in CMOS. |
| |
| 0230 |
Shadow RAM error, shadow RAM fails at offset nnnn. |
| |
| 0231 |
System RAM error, system RAM fails at offset nnnn. |
| |
| 0232 |
Extended RAM error, extended RAM fails at offset nnnn. |
| |
| 0250 |
System battery error, system battery is dead. |
| |
| 0251 |
System CMOS checksum bad, default configuration used. |
| |
| 0252 |
Password checksum bad. The password is cleared. |
| |
| 0260 |
System timer error |
| |
| 0270 |
Real time clock error |
| |
| 0271 |
Date and time error, neither the date nor the time is set in the computer. |
| |
| 0280 |
Previous boot incomplete, default configuration used. |
| |
| 0281 | Memory Size found by POST differed from CMOS. Memory Size found by POST differed from CMOS |
| |
| 02B0 | Diskette drive A error. Drive A: is present but fails the BIOS POST diskette tests. |
| |
| 02B1 | Diskette drive B error. Drive B: is present but fails the BIOS POST diskette tests. |
| |
| 02B2 | Incorrect drive A type, Type of floppy drive A: not correctly identified in Setup. |
| |
| 02B3 | Incorrect drive B type, Type of floppy drive B: not correctly identified in Setup. |
| |
| 02D0 | System cache error. RAM cache failed and BIOS disabled the cache |
| |
| 02F0 | CPU ID. CPU socket number for Multiprocessor error | ||
| 02F4 | EISA CMOS not writeable - ServerBIOS2 test error: Cannot write to EISA CMOS |
| |
| 02F5 | DMA test failed - ServerBIOS2 test error: Cannot write to extended DMA (Direct Memory Access) registers. |
| |
| 02F6 | Software NMI failed - ServerBIOS2 test error: Cannot generate software NMI (Non-Maskable Interrupt). |
| |
| 02F7 | Fail-safe timer NMI failed - ServerBIOS2 test error: Fail-Safe Timer takes too long |
| |
| 1801 | Attached docking station is not supported |
| |
| 1802 |
Unauthorized network card is plugged in, power off and remove the Mini PCI network card |
| |
| 1803 | Unauthorized daughter card is plugged in. Power off and remove the daughter card. |
| |
| 1810 | Hard disk partition layout error |
| |
进入上海新宇笔记本维修主力站点 |
|
免费服务电话:800 820 9120 |
笔 |
| 我们的地址:上海市南丹东路228弄3号楼402室 | |
| 我们的电话:021-64283052 64283432 | |
| 我们的传真:021-54254762 | |
| E-mail:13918440336@sohu.com | |
| 24小时报修热线:13391203680 赵先生(维修工程师) | |
最拿手维修: 松下,NEC,TCL,宏基,三星,LG,清华紫光 笔记本液晶屏维修,笔记本主板维修,笔记本电池维修... |
|
>>与我们客户服务取得联系<<< |
|
2005-2006 上海新宇笔记本维修中心公司地址:上海市南丹东路228弄3号楼402室
我们的电话:021-64283052 64283432 ; 我们的传真:021-54254762 E-mail:13918440336@sohu.com